Only ultra-precision ceramic bearings are used.
To balance rotor assemblies, we utilize a two-plane dynamic balancer
which offers many advantages over a simple vibration analyzer. The
imbalance in turbo pump rotors can only be eliminated by mass correction
in at least two planes perpendicular to the shaft axis. Our two
plane dynamic balancer pinpoints the angle and mass of imbalance.
Adjustments are carefully made until the balancer's microprocessor
determines the assembly's residual imbalance is within tolerances.
Turbo Vacuum achieves a Balance Quality Grade of G-1(ISO1940/1 &
ANSI S2.19) which provides superior bearing life. A report showing
the specifications to which your pump was balanced is included with
every rebuild.
Features and Benefits
• Complete Decontamination and Cleaning
• Analyzation and inspection
• All Seals, Bearing and wick/grease plugs replaced
• Reassembly with ceramic bearings
• Dual-Plane dynamic balancing
• 48-hour quality control test
• 12-month warranty on most units
• Balance specification reports
• Pump sealed and prepared for use or storage
• Expedite service available on all units
Turbo Pumps Serviced
• Alcatel Adixen
• Balzer
• Agilent
• Edwards
• Seiko Seiki
• KYKY
• Oerlikon Leybold
• Osaka
• Pfeiffer
• Sciex
• TYH
• Varian
Turbo Vacuum has Reconditioned Turbos Pumps.
|